Haptic system for laparoscopic, arthroscopic and thoracoscopic VR training
4DOF haptic device for laparoscopic VR simulation
Yaw · Side to side
±90°
Resolution 0.0055°
Peak strength 0.8 Nm
Pitch · Back and forth
±60°
Resolution 0.0055°
Peak strength 1.0 Nm
Rotation · Twist
Unlimited
Resolution 0.01°
Peak strength 0.10 Nm
Insertion · In and out
Unlimited
Resolution 5 µm
Peak strength 18 N
Peak strength can be held for a limited time. The Port is over-temperature protected and cooled by an internal fan. With an instrument inserted 100 mm, the sideways position resolution at its tip is roughly 20 µm.
| Applications | Laparoscopy, arthroscopy, thoracoscopy | Virtual reality simulation training. |
|---|---|---|
| Communication | USB (Micro-B to A) | To a USB 3.0 hub or directly to the computer. Current requirement 0.9 A. |
| Force loop | >6 kHz external | Through the simulation. |
| Power | Internal Li-Ion battery | Four 3.7 V cells, 37 Wh in total, charged via USB. An external 16.8 V charger (provided) charges four times faster. |
| Calibration | Automatic zero angle | Yaw and pitch. The Port blinks fast when it needs calibration; move it in a small circle around the zero position. |
| Minimum distance | 50 mm | Between Ports, without mechanical interference. |
| Weight | 1.75 kg |

Instrument handles, shafts and scope
Grasper
Force feedback
Clip Applier
Force feedback
Needle Driver
Sensing
Straight Tool
Sensing
Scope
Sensing
Standard 310 mm for laparoscopy and thoracoscopy, 210 mm for arthroscopy. Any length from 200 mm to 450 mm at purchase.
Standard set
Extended set
Mate a handle with a shaft and connect it to the IBox connector of the same colour. Handles with force feedback need red, orange, yellow or green. The black shaft is for the Scope.
| Handle grip (force feedback) | 0–100 %, typically 30° | Resolution 0.1 %, 0.01°, peak strength 10 N |
|---|---|---|
| Scope camera angle | 0–360°, unlimited turns | Resolution <0.1° |
| Scope zoom knob | 0–360°, unlimited turns | Resolution 32 ticks per turn |
Because of the Avatar's unique system with a Port that accepts a simple threaded/grooved instrument shaft, and instruments that are individually sensed/detected, adaptation to special instruments is straightforward.

The example shows an Echelon Flex 35 (ETHICON) which is equipped with sensors to interact with the Avatar System. Other examples are ETHICON Echelon Flex 3000, Covidien Signia staplers, Medtronic Endostitch.
Depending on the number and type of sensors needed, the instrument handle is either USB-connected, or connected to the IBox.
Reads the handles and drives their force feedback.
4DOF tracking device for laparoscopic VR simulation
0.0055°
Yaw and pitch resolution
3.6µm
Insertion resolution
~35mm
Minimum distance between Trocars
100g
Weight
Mount the Ports in your preferred way.

Fixed ramp on plate
Movable ramp on rail
Fixed workstation
Tool stand
Transportable Tri‑port
Follou's device library connects Haptic Avatar to your simulation, whatever language it is written in.
Your simulation
Python, C++, C#, Unity or any other environment
From Follou
Follou device library
A DLL on Windows, dylib on macOS, .so on Linux
Haptic Avatar
Ports, Trocars, IBox and Scope. One USB cable per device.
The library finds and identifies every connected Follou device. Your simulation reads positions and orientations and sets forces, at up to 7000 Hz for several devices (1000 Hz for the Trocar) and about 35 µs per update. For Unity, a ready-made prefab connects the devices automatically.
Avatar Port
HA-HD-001
IBox
HA-IB-001
Instrument Shaft
HA-IN-001
Grasper
HA-IN-002
Grasper Without Force
HA-IN-003
Needle Driver
HA-IN-004
Straight Tool With Pushbuttons
HA-IN-005
Clip Applier
HA-IN-006
Scope
HA-SD-001
Haptic Port Mounting Bracket
HA-FA-001
IBox Mounting Bracket
HA-FA-002
Fixed 20° Ramp Low
HA-FA-003
Movable 20° ramp Low
HA-FA-005
Base With 5 Rails
HA-BA-001
Workstation Base With 2 Mounting Brackets
HA-BA-002
Workstation Base With 3 Mounting Brackets
HA-BA-003
Instrument Holder Stand
HA-BA-004
Li-Ion battery charger
HA-AC-001
USB-hub
HA-AC-002
Double Footswitch Pedal
HA-ES-001
4DOF haptic device for laparoscopic VR simulation
Instrument handles, shafts and scope for Haptic Avatar
4DOF tracking device for laparoscopic VR simulation
Questions or a quote?
Contact us
Address
Ekvatorsvägen 8, 423 38 Torslanda, Sweden